Máy đo pH/ORP/Nhiệt độ để bàn Hanna HI 2223-02

( 1 Votes)
(Lượt xem : 837 )
Thông tin chi tiết

Máy đo pH/ORP/Nhiệt độ để bàn Hanna HI 2223-02

Hãng sản xuất: HANNA

Xuất xứ: Romania

Model: HI 2223-02

Calibration Check™ pH bench meter with logging up to 500 samples, Calibration Expiration Reminder, range: pH – 2.00 to 16.00 pH  mV ± 699.9 mV; ± 2000 mV, Temperature – 20.0 to 120.0 °C, 230V

Giá: Liên hệ 0977.459.400

The HI-2223-02 is a pH bench top meter featuring our exclusive Calibration Check™ diagnostics for both pH electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition, it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.

The HI-2223-02 also features five point calibration with seven standard buffers, Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function, measurements are stored and can be transferred to a PC through the USB port. Users can manually log up to 200 records and interval log up to 500 records.

This meter can measure using ORP electrodes (pH channel input), due to its capability to measure mV with a resolution up to 0.1 mV. 

Key features

  • pH Calibration Check™
  • On-screen electrode condition and response time
  • Up to five point calibration with seven standard buffers
  • Diagnostic alerts through icons
  • Automatic Temperature Compensation
  • Log up to 500 samples
  • GLP features


Supplied with

  • HI 1131B pH electrode and HI 7662 temperature probe
  • HI 76404N electrode holder
  • Starter pack of cleaning and buffer solutions
  • 12Vdc adapter
  • Instructions

 

Range pH –2.00 to 16.00 pH; –2.000 to 16.000 pH
  mV ±999.9 mV; ±2000 mV
  Temperature – 20.0 to 120.0 °C
Resolution pH 0.01 pH; 0.001 pH
  mV 0.1mV(± 999.9mV); 1mV(± 2000mV)
  Temperature 0.1 °C
Accuracy pH ±0.01 pH; ±0.002 pH
  mV ±0.2mV(± 999.9mV);
  Temperature ± 0.2 °C (excluding probe error)
pH Calibration   Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 2 custom buffers
Temperature Compensation   Manual or automatic from -20 to 120°C
Temperature Probe   HI 1131P glass body, single junction, refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe
PC Connection   USB
Data Logging   500 points