Máy đo đa chỉ tiêu Hanna HI 83214-02

( 0 Votes)
(Lượt xem : 487 )
Thông tin chi tiết

Máy đo đa chỉ tiêu Hanna HI 83214-02

Máy đo đa chỉ tiêu dùng trong lĩnh vực phân tích nước thải

Hãng sản xuất: HANNA

Xuất xứ: Romania

Model: HI83214-02

Giá: Liên hệ 0977.459.400

 

HI-83214-02 multiparameter COD meter and photometer allows operators to conduct a complete wastewater analysis using a single meter at the touch of a key pad.

This powerful all-in-one product is designed and built to perform COD analysis in accordance with EPA 410.4 and ISO 15705:2002 standards. Ensuring accurate and repeatable results, HI-83214-02 is the ideal tool for documenting waste water treatment processes.

To assist efficient data collection, the instrument can be connected to a PC through an RS232 serial port. Stored measurements can be downloaded using Hanna HI-92000 software.

Main benefits

  • Easy COD measurement: pre-calibrated to measure COD levels at three ranges - all at the touch of a key pad
  • Outstanding measurement quality: an advanced optical system ensures high accuracy measurements across the range
  • Space saving: neat and compact, the HI 83214 eliminates clutter and saves space in the laboratory


A plus for tight budgets
The HI 83214 bench meter can also be used to measure total ammonia, nitrogen and total reactive phosphorus as well as chemical oxygen demand. 

Its multiparameter facility makes this meter particularly suitable for a wide range of applications and a great plus for operators and organisations working to tight budgets.

On or off-site testing
This photometer can be used both in the laboratory and on location for on-site testing.

Designed to be as easy to use as possible, it can be used by operators at all skill levels.

Supplied with

  • 5 cuvettes
  • Batteries
  • 12 Vdc adapter
  • Instructions
  • Reagent is not supplied as standard with the HI 83214 as ranges vary


More about COD
Used as a measurement of pollutants, COD is measured on both influent and effluent water to give an indication of the efficiency of the treatment process. This is normally expressed as COD removal - measured as a percentage of the organic matter purified during the cycle. 

COD measurement can also be used to check pollutant levels in other applications including power plants, chemical manufacturing plants, commercial laundries, pulp and paper mills, agriculture and animal waste run-off as well as in environment studies and general education. 

Selecting the right reagent
COD levels vary depending on the application and process measuring points. 
To help select the correct reagent for your particular requirements, Hanna offers three separate reagent ranges in boxes of 25 vials.

Light Source   tungsten lamps with narrow-band interference filters
Light Detector   silicon photocell
Power Supply   external 12 VDC power adapter or built-in rechargeable battery
Auto-off   after 10 min. of non-use in measuring mode; after 1 hour of non-use in calibration mode with last reading reminder
Dimensions   235 x 200 x 110 mm (9.2 x 7.87 x 4.33")
Weight   0.9 Kg (2 lbs.)
Environment   0 to 50°C (32 to 122°F); RH max 90% non-condensing

 

 

 

 

Parameter

Range

Resolution

Accuracy*

Method

Reagent Code

Ammonia LR

0.00 to 3.00 mg/L (ppm) as NH<sub>3</sub>-N

0.01 mg/L

±0.10 mg/L ±5% of reading

Nessler

HI93764A-25 (25 tests)

Ammonia HR

0 to 100 mg/L (ppm) as NH<sub>3</sub>-N

1 mg/L

±1 mg/L ±5% of reading

Nessler

HI93764B-25 (25 tests)

Chlorine,** Free

0.00 to 5.00 mg/L (ppm)

0.01 mg/L below 0.99 mg/L; 0.1 mg/L above 0.99 mg/L

±0.03 mg/L ±4% of reading

DPD

HI93701-01 (100 tests)

 

HI93701-03 (300 tests)

Chlorine,** Total

0.00 to 5.00 mg/L (ppm)

0.01 mg/L below 0.99 mg/L; 0.1 mg/L above 0.99 mg/L

±0.03 mg/L ±4% of reading

DPD

HI93711-01 (100 tests)

 

HI93711-03 (300 tests)

Nitrate

0.0 to 30.0 mg/L (ppm) as NO<sub>3</sub>-N

0.1 mg/L

±1.0 mg/L ±5% of reading @ 20°C

chromotropic acid

HI93766-50 (50 tests)

Nitrogen, Total LR

0.0 to 25.0 mg/L (ppm)

0.1 mg/L

±1.0 mg/L ±5% of reading @ 20°C

chromotropic acid

HI93767A-50 (50 tests)

Nitrogen, Total HR

10 to 150 mg/L (ppm) as N

1 mg/L

±3 mg/L ±4% of reading

chromotropic acid

HI93767B-50 (50 tests)

Phosphorus, Acid Hydrolyzable

0.00 to 1.60 mg/L (ppm) as P

0.01 mg/L

±0.05 mg/L ±5% of reading

ascorbic acid

HI93758B-50 (50 tests)

Phosphorus, Reactive

0.00 to 1.60 mg/L (ppm) as P

0.01 mg/L

±0.05 mg/L ±5% of reading

ascorbic acid

HI93758A-50 (50 tests)

Phosphorus, Reactive HR

0.0 to 32.6 mg/L (ppm) as P

0.1 mg/L

±0.5 mg/L ±5% of reading

vanadomolybdophosphoric acid

HI93763A-50 (50 tests)

Phosphorus, Total

0.00 to 1.15 mg/L (ppm) as P

0.01 mg/L

±0.05 mg/L ±6% of reading

ascorbic acid

HI93758C-50 (50 tests)

Phosphorus, Total HR

0.0 to 32.6 mg/L (ppm)

0.1 mg/L

±0.5 mg/L ±5% of reading

vanadomolybdophosphoric acid